Installation
The Fixing Kit should contain: 1 Drilling Template, 3 Screws, 3
Rawlplugs and 1 Mounting Bracket.
Wall Mounted Operation (see Fig. 2)
Suggested Fixings
SOLID BRICK/BLOCK: No. 8 Rawlplug inserts, 6mm drill bit.
PLASTERBOARD: If possible locate studding and use No. 8
woodscrews directly into the wood, otherwise M5 rawlplug intersets
are suitable.
NOTE: FOR OTHER WALL TYPES (e.g. Timber frame and hollow
concrete) SEEK SPECIALIST ADVICE.
1. Select the position for the heater ensuring there is clearance
from any furniture and fi ttings of at least 150mm above the
heater, 50mm below and 25mm each side. Curtains must
not be closer than 150mm from the top of theheater.
2. Position the drilling template provided on the wall ensuring
it is level. Mark the position of the relevant holes on the
wall at the edge of template. Before drilling check that the
distance between the hole centres is correct, 340mm for
400W Models and 540mm for 800W models (see Fig. 2).
Fig. 2
Positioning the Heater
Select the position for the heater ensuring there is clearance from
any furniture and fi ttings of at least 150mm above the heater, 50mm
below (wall mounted) and 25mm each side. Curtains must not be
closer than 150mm from the top of the heater.
Free Standing Operation (see Fig. 1)
NEVER USE THE HEATER FREE STANDING WITHOUT THE
FEET FITTED (FEET ARE PACKED SEPARATELY IN CARTON).
1. Lay the heater on its front.
2. Remove the two star head screws from the base of the
heater using a x-head screwdriver.
3. Place feet over base of heater, align holes and engage hook
on foot into the recess on the back of the heater - see Fig.
1.
4. Replace the screws but do not overtighten.
Fig. 1
Rear View
3. Drill the wall at the three marked positions and fi t the wall
plugs.
Ensure template has been removed.
4. Fix two No. 8 screws to the top two holes leaving 3mm of
the screw exposed. Hang the heater on the screws.
5. Fit the bottom bracket, found in the fi xing kit, in the slot at
the base of the heater and screw the bracket to the wall.
Test that the heater is now securely fi xed to the wall.
130mm
340mm - 400W
540mm - 800W
95mm
150mm
50mm
420mm
25mm 25mm
130mm
Drilling Holes
Bracket
Electrical Connection
WARNING THIS APPLIANCE MUST BE EARTHED
If the socket outlets in your home are not of the 13 amp BS1363
type they will not accept the plug connected to this heater,
therefore cut off the plug. When cut off this plug can constitute
a shock hazard if inserted into a socket outlet. It must therefore
be disposed of safely.
Before wiring the appropriate plug please note that the wires in this
mains lead are coloured in accordance with the following code.
GREEN/YELLOW: EARTH
BLUE: NEUTRAL
BROWN: LIVE
Connect the Green/Yellow wire to the terminal marked E or the
earth symbol
or coloured Green or Green/Yellow.
Connect the Brown wire to the terminal marked L or coloured Red.
Connect the Blue wire to the terminal marked N or coloured Black.
DO NOT connect the Brown (Live) or the Blue (Neutral) wires
to the Earth terminal of your 13 amp plug. If the terminals of the
plug are unmarked or you are in any doubt, consult a qualifi ed
electrician.
CAUTION: If you use this heater in conjunction with a thermal
control, programme controller, timer or any other device which
switches the heater on automatically observe all safety warnings
at all times.
Comentarios a estos manuales