Dimplex BF33DX Manual de usuario

Busca en linea o descarga Manual de usuario para Chimeneas Dimplex BF33DX. Installation Guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 1 - ELECTRIC FIREPLACE

INSTALLATION GUIDE FOR THE ELECTRIC FIREPLACE MODEL NUMBERS: BF33ST/DX BF39ST/DX BF45ST/DX 7206350200REV06

Pagina 2

240 VOLT MAIN WALL SWITCH WIRING DIAGRAM 8 FIREPLACE JUNCTION BOX 240 V POWER SUPPLY (BREAKER PAN

Pagina 3 - MODEL SPECIFICATIONS

MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NOTE: This option should not be used with the remote control kit. NOTE: Before installing the unit have t

Pagina 4 - SECTION A: FRAMING

120 VOLT MAIN WALL SWITCH WIRING DIAGRAM 10 FIREPLACE JUNCTION BOX 120 V POWER SUPPLY (BREAKER PA

Pagina 5 - MOUNTING FLANGES

MAIN POWER WALL SWITCH WIRING FOR 120 VOLT NO HEAT INSTALLATION NOTE: This option should not be used with the remote control kit. NOTE: Before insta

Pagina 6 - 240 VOLT INSTALLATION

120 VOLT MAIN WALL SWITCH WIRING DIAGRAM NO HEAT INSTALLATION FIREPLACE JUNCTION BOX 120 V POWER S

Pagina 7 - 120 VOLT INSTALLATION

SECTION E: HEATER WALL SWITCH AND WALL THERMOSTAT WIRING OPTIONS HEATER WALL SWITCH WIRING FOR 120/240 VOLT NOTE: Before installing the unit

Pagina 8 - (NO HEAT INSTALLATION)

HEATER WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION)

Pagina 9 - 240 VOLT INSTALLATIONS

WALL MOUNTED THERMOSTAT WIRING FOR 120/240 VOLT NOTE: Before installing the unit complete the following: 1. Install main power connection with app

Pagina 10 - WIRING DIAGRAM

WALL MOUNTED THERMOSTAT WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER CONNECTION)

Pagina 11 - 120 VOLT INSTALLATIONS

FLAME OVERRIDE SWITCH WIRING FOR 120/240 VOLT NOT AVAILABLE WITH NO HEAT INSTALLATION NOTE: The fireplace can be wired to have a wall switch operat

Pagina 12 - 120 VOLT MAIN WALL SWITCH

CONTENTS PAGE 1 Listings and Code Approvals PAGE 1 Model Specifications PAGE 1 Step-by-Step Installation Section A PAGE 2 Framing

Pagina 13 - NO HEAT INSTALLATION

FLAME OVERRIDE WALL SWITCH WIRING DIAGRAM FOR 120/240 VOLT (SEE SECTION C OR SECTION D FOR MAIN POWER C0NNECTION) NOT AVAILABLE WITH NO HEAT INSTALLA

Pagina 14

WIRING DIAGRAM LOWER SECTION 19 BLACKWHITEBROWNCITORBYPASS HARNESSLOWER HARNESSWHITEORANGE

Pagina 15 - HEATER WALL SWITCH WIRING

WIRING DIAGRAM UPPER SECTION 20 CUT-OUTMELEMENT #2ELEMENT #1264153BLOWER WHEELBLW. MOTORBR

Pagina 16

WIRING SCHEMATIC 21

Pagina 17 - 120 / 240VOLT INSTALLATIONS

1367 Industrial Road Cambridge, Ontario Canada, N1R 7G8 1-888-DIMPLEX1-888-346-7539 App

Pagina 18 - WALL BOX

LISTINGS AND CODE APPROVALS The BF series fireplaces have been tested in accordance with the UL 2021 and CSA C22.2 No. 46 standards for fixed and loc

Pagina 19 - FLAME OVERRIDE SWITCH WIRING

WARNING Ensure method of installation does NOT obscure the air intake slots on bottom front of unit in any manner. (see diagram in Section A) SECTION

Pagina 20 - DIAGRAM FOR 120/240 VOLT

VOLTAGE SELECTOR SWITCH LOCATION IMPORTANT: Ensure that the incoming power supply voltage matches the setting of the voltage selector switch. NOTE

Pagina 21 - LOWER SECTION

SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use

Pagina 22 - UPPER SECTION

SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) IMPORTANT: The unit is factory configured for 208/240 volt operation NOTE: Use 2

Pagina 23 - WIRING SCHEMATIC

SECTION C: FACTORY SETTING WIRING (WITHOUT MAIN POWER WALL SWITCH) (NO HEAT INSTALLATION) IMPORTANT: The unit is factory configured for 208/240 vol

Pagina 24 - 1-888-DIMPLEX

SECTION D: MAIN POWER WALL SWITCH WIRING OPTIONS MAIN POWER WALL SWITCH WIRING FOR 240 VOLT NOTE: This option should not be used with the remote c

Comentarios a estos manuales