23
Important Notes on Operation
The room air conditioner may not be used for any
purpose other than room cooling, heating or
dehumidification or air circulation (fan).
Heating operation
The device operates with heat pump switching.
Heat is extracted from the outside air, then led to
the indoor unit and given off in the room to be
heated.
Heat output reduces as the temperature of the
outside air falls.
If the device is not providing sufficient heat for the
room, we recommend operating it in combination
with another heater.
Heat pump air conditioners circulate the warm air
in order to heat the entire room. It therefore takes
some time until the entire room is warm (also
depends on the external temperature and the
heating requirement).
Automatic de-icing
When external temperatures are low and air
humidity is high, heating operation can cause the
formation of ice on the outdoor unit which reduces
the heat output. In this case, the device switches
automatically to the “De-frost” operating mode for
10 – 15 minutes, heating is interrupted and the
fans cease to operate.
An LED on the indoor unit blinks while the device
is in “De-frost” mode.
When room and external temperatures are too
high
When, in heating operation, both room and
external temperatures are too high, the fan of the
outdoor unit may switch off periodically (protective
function).
Power cuts
After a power cut the devices commence
operation again in the operating mode last set
(with the temperature setting last stored). This
occurs in cooling and dehumidifying mode with
the normal delay at start (approx. 3 min.); in
heating operation this restart phase can last up to
17 minutes. The settings of the air flow fins
(SWING) can be lost through the power cut.
Permissible temperature and humidity
ranges
In the external temperature range
device R 407 C: from approx. 0 °C to +43 °C
device R410 A: from approx. -5 °C to +43 °C
Outdoor humidity:
approx. 40 to 80 %
Room temperature range:
device R 407 C: from approx. +16 °C to
+30 °C
device R 410 A: from approx. +16 °C to
+30 °C
Cooling
Room humidity:
approx. 40 to 80 %
If the device is exposed to high humidity
over a long period, condensation may
form and drip down.
External temperature:
approx. 20 °C to 43 °C
Outdoor humidity:
approx. 40 to 80 %
Room temperature range:
approx. 20 °C to 30 °C
Dehumi-
dification
Room humidity:
approx. 40 to 80 %
If the device is exposed to high humidity
over a long period, condensation may
form and drip down.
In the external temperature range
device R 407 C: from approx. -7 °C to +43 °C
device R410 A: from approx. -7 °C to +43 °C
Outdoor humidity:
approx. 40 to 80 %
Room temperature range:
device R 407 C: from approx. +16 °C to
+30 °C
device R 410 A: from approx. +16 °C to
+30 °C
Heating
Room humidity:
approx. 40 to 80 %
If the device is exposed to high humidity
over a long period, condensation may
form and drip down.
If the device is exposed to higher temperatures than
those specified here, the automatic safety
mechanism may be triggered and operation may be
interrupted.
If the device is exposed to lower temperatures than
those specified here, ice may form on the heat
exchanger, which can cause water (condensation) to
run out and lead to other functional defects.
General notes on efficient operation:
- Windows and doors should not be kept open during air conditioning!
- Select the air direction best suited to your purpose (down for heating, up for cooling)!
- When cooling, the room temperature selected should not be more that 5 °C below the external temperature!