Dimplex DC12 Manual de servicio Pagina 6

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 5
PowerFlex 700L Technical Data
6 Publication 20L-TD001A
Catalog Number Explanation
To interpret the meaning of a catalog number, match the values of the catalog number code in positions a, b, c, etc. with
the tables labeled a, b, c, etc. below.
Position
1-3 4 5-7 8 9 10 11 12 13 14 15 16 17 18
20L E 800 A 0 E N N A N 1 0 W A
a bcdefghijklmn
a
Drive
Code Type
20L PowerFlex 700L
b
Voltage Rating
Code Voltage Ph.
C 400V AC 3
D 480V AC 3
E 600V AC 3
F 690V AC 3
c1
ND Rating
400V, 60 Hz Input
Code Amps kW Hp Frame
360 360 200 268 2
650 650 370 500 3A
1K2 1250 715 960 3B
c2
ND Rating
480V, 60 Hz Input
Code Amps kW Hp Frame
360 360 224 300 2
650 650 445 600 3A
1K2 1250 860 1150 3B
c3
ND Rating
600V, 60 Hz Input
Code Amps kW Hp Frame
425 425 345 465 3A
800 800 650 870 3B
c4
ND Rating
690V, 60 Hz Input
Code Amps kW Hp Frame
380 380 355 475 3A
705 705 657 881 3B
d
Enclosure
Code Enclosure
Conformal
Coating
A
IP20, NEMA/UL
Type 1 §
No
N
IP00, Open
Chassis
No
§ Frames 3A & 3B complete drive.
Frame 2 only.
e
HIM
Code Operator Interface
0 No HIM/Blank Cover
3 Full Numeric LCD (Frame 2 Only)
C
Full Numeric LCD, Door Mount
(Frames 3A & 3B Only)
f
Documentation
Code Documents Ship Carton
E English Doc Set Yes
N No Documentation Yes
g
Brake
Code w/Brake IGBT
oNN
h
Brake Resistor
Code w/Resistor
oNN
i
Equipment Type
Code Description Frame
A
Complete
Regenerative Drive
2, 3A & 3B
j
Comm Slot
Code
Communication
Option
DPI™ User
Installed Kit
Cat. No.
N None N
C
DPI ControlNet (Coax)
20-Comm-C
D DPI DeviceNet 20-Comm-D
E DPI EtherNet/IP 20-Comm-E
R DPI RIO 20-Comm-R
S DPI RS-485 DF1 20-Comm-S
1
DriveLogix™
ControlNet (Coax)
-
2
DriveLogix ControlNet
Redundant (Coax)
-
3
DriveLogix ControlNet
(Fiber)
-
4
DriveLogix ControlNet
Redundant (Fiber)
-
5
DriveLogix DeviceNet
(Open Conn.)
-
6
DriveLogix EtherNet/IP
-
700 Vector Control uses DPI comm. slot
options only.
DriveLogix comm. slot options require 700S
Phase II Control with DriveLogix5730.
For 700S Phase II Control with
DriveLogix5730, comm. slot option selections
are mutually exclusive. For two communication
adapters, (DPI and DriveLogix), select the
DriveLogix comm. slot option and order the
DPI user installed kit catalog number
separately.
Vista de pagina 5