User interface (Fig.1)
A Display monitor
B READINGS
C Key to access menu
D key to access SETTINGS menu
E key to access ALARM log
F Keys to scroll/increase-decrease parameters
R
SET
dj
A
B
C
D
E
F
User interface and setting display
Display visualisation (Fig.2)
1 SETTINGS menu currently displayed
2 ALARMS menu currently displayed
Flashes when compressor has "FORCE OFF" status
3 Parameter index
4 Parameter abbreviation / Parameter value
5 Cooling mode
6 Heating mode
7 Indicator of current alarm status
8 Indicator of current compressor operational mode (this
indication can have different flashing frequencies).
9 Indicator of stop in progress
A B
The main user interface has a LED display with a touch-keys pad.
The display is are arranged in three menus:
• READINGS menu (key (C) Fig.1)
Displays the system’s current readings, no changes to the
settings can be made in this menu.
• SETTINGS menu (key (D) Fig.1)
Containing all the parameters that the user can modify accor-
ding to system requirements; these parameters are grouped
together in various sub-menus:
- USER menu (Password 000);
- INSTALLER menu (Password 030);
- ELECTRIC HEATER menu (Password 001);
• ALARM log (key (E) Fig.1)
The alarm log records ‘alarms’ and ‘pre-alarms’ caused by a
unit error and/or malfunction.
During normal opperation, the monitor displays the last pa-
rameter modifi ed; if no other keys are pressed for at least
5 minutes, the monitor activates the screensaver mode
(this function can be set via the parameter (I) in the INSTAL-
LER menu).
To display parameters and/or readings, 4 fi gures are used;
the fi rst is the indicator i.e. a number allowing the user
to know which parameter or reading he is displaying (Fig.3).
SET
dj
5
6 7
8
9
4
1
2
3
Fig.1
Fig.2
Fig.3
User interface (Fig.3)
A Parameter index
B Parameter abbreviation / Parameter value
Comentarios a estos manuales