10EN -
List of indexes and relative readings in the USER MENU (no password)
READINGS menu
To access the readings menu, press the
key in (Fig.4); once the readings menu
has been accessed, the monitor will
display the readingis index and a 3-cha-
racter string that identifi es it; the string
will be displayed for one second, after
which it is replaced by the value of the
reading itself. To move on to the next
reading, press the key in (Fig.5);
to go
back to the previous one, press the key
in (Fig.6). Every time you pass from one
reading to another, apart from the chan-
ge in the index value you will also see
(for one second) the string identifying
the current reading (it is also possible,
to identify any reading via the value of
the index, comparing it with the table
below).
R
R
R
Fig.4 Fig.5 Fig.6
Index - String Meaning of the reading
Water flow temperature
Water return temperature
Evaporator coil temperature
Compressor gas discharge
temperature
Outside air temperature
High pressure trasducer
Low pressure trasducer
Set temp P/I control
Flow temp safety force-off
Index - String Meaning of the reading
Compressor time until start
Hours of operation (thousands)
Hours of operation (units)
Compressor pickup current
(thousands)
Numbers of compressor starts
Software release
Minor software releases
Actual set temp in use
Pressure drop